	<item>
		<title>Baur Frida VLF Test Set 23kVAC</title>
		<link>http://www.precisefacilities.com.au/product/baur-frida-vlf-test-set-23kvac/</link>
		<comments>http://www.precisefacilities.com.au/product/baur-frida-vlf-test-set-23kvac/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 06:36:29 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=27</guid>
		<description><![CDATA[<p>The Baur Frida 23kVAC is a portable and high performance VLF test set for performing high voltage testing and nondestructive cable condition diagnostics. The Baur Frida 23kVAC can be used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV nominal voltage as well as insulation testing on electrical equipment. It is quick and easy to set up, includes automatic testing and diagnostic sequences and the patented VLF truesinus technology guarantees maximum measurement accuracy.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/baur-frida-vlf-test-set-23kvac/">Baur Frida VLF Test Set 23kVAC</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The Baur Frida 23kVAC VLF test set is designed for the testing of electrical equipment and medium-voltage cables up to 20 kV nominal voltage. The fully automated and individually programmable diagnostic sequences which include evaluation allow for easy and intuitive operation and cable stress is minimized with stepwise increases in voltage and optimized test durations. The test set features integrated measurement data storage with export available via a USB interface.</p>
<h3>Brief Specs:</h3>

		</div> 
	</div> <div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Applications</h4>
<ul>
<li>On-site testing of medium voltage cables according to VDE DIN 0276-620/621 (CENELEC HD 620/621), IEEE P 400.2-2004, IEEE 400-2001</li>
<li>Cable sheath testing / Sheath fault location</li>
<li>Insulation tests on electrical equipment, such as rotating machines (motors and generators) according to IEEE 433</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Features</h4>
<ul>
<li>Compact, easy portable testing equipment</li>
<li>VLF truesinus high voltage source</li>
<li>Fully automatic programmable test sequences</li>
<li>Data communication and saving via USB-interface</li>
<li>Integrated cable case with connection cable</li>
<li>Automatic, integrated discharging device</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div></div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/baur-frida-vlf-test-set-23kvac/">Baur Frida VLF Test Set 23kVAC</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/baur-frida-vlf-test-set-23kvac/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>HV Diagnostics HVA30 30kVDC VLF Test set</title>
		<link>http://www.precisefacilities.com.au/product/hv-diagnostics-hva-30-30kvdc-vlf-test-set/</link>
		<comments>http://www.precisefacilities.com.au/product/hv-diagnostics-hva-30-30kvdc-vlf-test-set/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 07:32:17 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=75</guid>
		<description><![CDATA[<p>The single piece HVA30 is a light, compact and advanced high voltage VLF test system primarily designed for the AC Hipot testing of extruded medium voltage cable systems but is also suitable for testing transformers, switchgear, rotating machines and other electrical apparatus. It offers fully automatic testing sequences, built in storage of test results, smooth load independent and symmetrical Sinewave HV outputs, DC and AC VLF outputs, capacitance and insulation resistance (mega-ohmmeter) measurements, accurate RMS metering, integrated discharge and transient protection.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-diagnostics-hva-30-30kvdc-vlf-test-set/">HV Diagnostics HVA30 30kVDC VLF Test set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The HV Diagnostics HVA30 30kVDC VLF Test set instrument is capable of testing 0.5µF (Approximately 1500m of cable) at 0.1Hz and 33kV peak. The frequency of the output can also be reduced allowing even larger capacitance loads to be tested, at 0.02Hz, approximately 7620m of cable can be tested. Test sequences are simple to setup or the operator can select test sequences in either automatic or manual mode. As well as the variable frequency VLF output, dual polarity DC and cable jacket or sheath testing output modes are available. The HVA30 will automatically calculate the optimum frequency to be selected for larger loads.</p>
<p>The load independent symmetrical output waveform avoids the potentially destructive space charge effects caused by DC polarization that occurs in aged extruded cables such as XLPE/PE/EPR, causing them to fail prematurely when exposed to conventional high voltage DC or from a test instrument with large non-symmetrical output waveforms.. Should a breakdown occur during testing the actual voltage at which it occurred is displayed and recorded. If cable burning (fault conditioning) mode is activated the fault resistance can be conditioned to allow easier and less stressful fault location techniques to be applied. Test results are stored in the instrument&#8217;s onboard memory allowing for easy retrieval and download to a PC for review and analysis.</p>
<h3>Brief Specs:<b><br />
</b></h3>
<ul>
<li>VLF (0.1Hz), DC (±), Cable Fault Conditioning (Burning) and Sheath/Jacket Testing modes.</li>
<li>Fully automatic or manual cable test sequences.</li>
<li>True Symmetrical Sinusoidal, load independent, output waveform across full load range.</li>
<li>Real-time display of actual output waveform.</li>
<li>Easy to use, ergonomic, menu guided, large backlight user interface.</li>
<li>Large output load capability (up to 5 µF).</li>
<li>Automatic and integrated load capacitance measurement with optimum frequency selection.</li>
<li>No oil or arcing contacts that require routine maintenance.</li>
<li>Short circuited protected with active arc management regulation, avoids nuisance tripping when dielectric failure occurs.</li>
<li>Status display of all important safety functions and messages.</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-diagnostics-hva-30-30kvdc-vlf-test-set/">HV Diagnostics HVA30 30kVDC VLF Test set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/hv-diagnostics-hva-30-30kvdc-vlf-test-set/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>HV Diagnostics HVA60 60kVDC VLF Test Set</title>
		<link>http://www.precisefacilities.com.au/product/hv-diagnostics-hva60-60kvdc-vlf-test-set/</link>
		<comments>http://www.precisefacilities.com.au/product/hv-diagnostics-hva60-60kvdc-vlf-test-set/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 07:32:49 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=76</guid>
		<description><![CDATA[<p>The HVA60 provides a versatile high voltage power source suitable for testing electrical plant including cables: XLPE, PE, EPR, PILC, capacitors, switchgear, transformers, rotating machines, insulators and bushings. It features a variable frequency true sinewave VLF output and selectable dual polarity DC and cable jacket or sheath testing outputs modes. Test results are stored in the onboard memory allowing easy retrieval and download to a PC/Laptop for review and analysis.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-diagnostics-hva60-60kvdc-vlf-test-set/">HV Diagnostics HVA60 60kVDC VLF Test Set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The load independent, symmetrical output waveform of the HVA60 avoids the potentially destructive space charge effects caused by DC polarization that occurs in aged extruded cables such as XLPE / PE / EPR, causing them to fail prematurely when exposed to conventional high voltage DC or to test instruments with large non-symmetrical output waveforms. The HVA60 is capable of testing 1µF (approximately 3000m of cable) at 0.1Hz and 60kV peak. The frequency of the output can also be reduced allowing even larger capacitance loads to be tested. At 0.02Hz, approximately 15,000m of cable can be tested.</p>
<p>Applied test voltage, current, capacitance, resistance and time are displayed and recorded with the output waveform being displayed in real-time. If a breakdown occurs during testing, the actual voltage at which it occurred is also displayed and recorded. If cable burning (fault conditioning) mode is activated, the fault resistance can be conditioned to allow easier and less stressful fault location techniques to be applied. The HVA60 is easily programmable to setup or the user can select test sequences in either automatic or manual mode.</p>
<h3>Brief Specs:</h3>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Input voltage</h4>
<ul>
<li>88 — 264 V 50 / 60Hz single phase</li>
</ul>
<h4>Output voltage</h4>
<ul>
<li>Sinusoidal: 0 — 60kV peak</li>
<li>DC: ±0 — 60kV</li>
<li>Square wave: 0 — 60kV peak</li>
<li>Accuracy: ± 1%</li>
</ul>
<h4>Output current</h4>
<ul>
<li>0 —50mA. Resolution 1μA</li>
<li>Accuracy: ± 1%</li>
</ul>
<h4>Resistance range</h4>
<ul>
<li>0.1MΩ &#8211; 20GΩ</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Output frequency</h4>
<ul>
<li>0.02 &#8211; 0.1 Hz. In steps of 0.01 Hz</li>
</ul>
<h4>Output load (based on a cable capacitance 330pF/metre)</h4>
<ul>
<li>1.0μF at 0.1Hz at 43kV rms (approx 3km of cable)</li>
<li>2.0μF at 0.05Hz at 43kV rms (approx 6km of cable)</li>
<li>5.0μF at 0.02Hz at 43kV rms (approx 15km of cable)</li>
<li>50μF at reduced voltage and/or frequency</li>
</ul>
<h4>Output mode</h4>
<ul>
<li>AC (VLF) Symmetrical and load independent over full range</li>
<li>DC positive and negative polarity</li>
<li>Burn / Fault condition or Fault trip mode</li>
<li>Jacket / Sheath testing</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-diagnostics-hva60-60kvdc-vlf-test-set/">HV Diagnostics HVA60 60kVDC VLF Test Set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/hv-diagnostics-hva60-60kvdc-vlf-test-set/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>HV Diagnostics HVA90 90kVDC VLF Test Set</title>
		<link>http://www.precisefacilities.com.au/product/hv-diagnostics-hva90-90kvdc-vlf-test-set/</link>
		<comments>http://www.precisefacilities.com.au/product/hv-diagnostics-hva90-90kvdc-vlf-test-set/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 07:33:21 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=77</guid>
		<description><![CDATA[<p>The HVA90 features fully automatic or manual cable test sequences for VLF (0.1Hz), DC (±), Cable Fault Conditioning (Burning), and Sheath/Jacket testing with a true symmetrical sinusoidal load independent output waveform across the full load range. It has a large output load capability (up to 10μF) and automatic and integrated load capacitance measurement with optimum frequency selection. The HVA90 has an easy to use menu guided user interface that displays the actual output wave form in real time. Results are stored in the instrument’s onboard memory allowing easy retrieval and download for review and analysis.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-diagnostics-hva90-90kvdc-vlf-test-set/">HV Diagnostics HVA90 90kVDC VLF Test Set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<div>
<p>The HV Diagnostics HVA90 VLF test set can operate in dual polarity DC and cable jacket or sheath testing output modes or simple utilise its variable frequency VLF output. . It is easily programmable allowing the operator to setup or select test sequences in either automatic or manual mode. The applied test voltage, current, capacitance, resistance and time are displayed and recorded. The HVA90 is capable of testing 1μF (Approx. 3300m) at 0.1Hz and 64kV RMS and the frequency of the output can also be reduced allowing even larger capacitance loads, at 0.01Hz approximately 33,000m of cable can be tested. To assist the operator, the instrument will automatically calculate the optimum frequency to be selected for larger loads.</p>
<p>The load independent, symmetrical output waveform avoids the potentially destructive space charge effects caused by DC polarization that occurs in aged extruded cables such as XLPE / PE / EPR, causing them to fail prematurely when exposed to conventional high voltage DC or from a test instrument with large non-symmetrical output waveforms. Should a breakdown occur during testing, the actual voltage at which it occurred is displayed and recorded. If cable burning (fault conditioning) mode is activated, the fault resistance can be conditioned to allow easier and less stressful fault location techniques to be applied.</p>
<h3>Brief Specs:</h3>
</div>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Input Voltage</h4>
<ul>
<li>210-265V 50Hz</li>
</ul>
<h4>Output Voltage</h4>
<ul>
<li>Sinusoidal: 0-90 kV peak, Symmetrical, 64kV rms</li>
<li>DC: ± 0-90 kV</li>
<li>Squarewave: 90kV</li>
<li>Accuracy ± 1%</li>
<li>Resolution 0,1kV</li>
</ul>
<h4>Output Current</h4>
<ul>
<li>0-40mA (Resolution 1 μA)</li>
<li>Accuracy ± 1%</li>
</ul>
<h4>Resistance Range</h4>
<ul>
<li>0.1 MΩ ….5 GΩ</li>
</ul>
<h4>Output Frequency</h4>
<ul>
<li>0.01….0.1Hz in steps of 0.01Hz</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Output Load</h4>
<ul>
<li>1.0μF @ 0.1Hz @ 64kV RMS (Approx 3300m of cable)*</li>
<li>1,2μF @ 0.1Hz @ 57kV RMS (Approx 3600m of cable)*</li>
<li>10μF @ 0.01 Hz @ 64kV RMS (Approx 33000m of cable)*</li>
<li>10μF Maximum Capacitance</li>
</ul>
<p>* Based on a cable capacitance of 300pF/m</p>
<h4>Output Modes</h4>
<ul>
<li>AC (VLF) Symmetrical and load independent across full range</li>
<li>DC (plus or negative polarity)</li>
<li>Burn / Fault Condition or Fault Trip Mode</li>
<li>Jacket / Sheath Testing</li>
</ul>
<h4>Metering</h4>
<ul>
<li>Voltage and Current (True RMS and/or peak)</li>
<li>Capacitance, Resistance, Time, Flashover Voltage</li>
</ul>