	<item>
		<title>Powershield Centurion 3000VA/2400W UPS</title>
		<link>http://www.precisefacilities.com.au/product/powershield-centurion-3000va2400w-ups/</link>
		<comments>http://www.precisefacilities.com.au/product/powershield-centurion-3000va2400w-ups/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 08:24:01 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=114</guid>
		<description><![CDATA[<p>The Powershield Centurion UPS provides a permanent backup power solution for systems such as servers, critical power applications, items in remote areas, utilisation of light to heavy industrial equipment, generator powered environments and applications that require remote connectivity. Some of the included features are true online double conversion, a wide input voltage range (110-300 VAC), input power factor correction 0.98 and a 50Hz/60Hz frequency converter mode.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/powershield-centurion-3000va2400w-ups/">Powershield Centurion 3000VA/2400W UPS</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>Ideal for shutdowns or when a generator is to be used, the Powershield Centurion UPS will help save costs on repairing expensive equipment damaged due to power fluctuations. Featuring true Online Double Conversion, a wide input voltage range (110-300 VAC), input power factor correction 0.98 and 50Hz/60Hz frequency converter mode. It also has programmable power outlets, and an emergency power off function (EPO). Communication is via multiple USB RS232 SNMP and AS400 ports and all monitoring and shutdown software is included.</p>
<h3>Brief Specs:</h3>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h3>Input</h3>
<p><strong>Voltage Range:</strong> Low Line Transfer 160 VAC / 140 VAC / 120 VAC / 110 VAC &plusmn; 5 % (based on load percentage 100% &#8211; 80 % / 80 % &#8211; 70 % / 70 &#8211; 60 % / 60 % &#8211; 0)<br /><strong>Low Line Comeback:</strong> 175 VAC &plusmn; 5 %<br /><strong>High Line Transfer:</strong> 300 VAC &plusmn; 5 %<br /><strong>High Line Comeback:</strong> 47.5Hz ~ 52.5Hz or 57Hz ~ 63Hz<br /><strong>Frequency Range (Synchronized Range):</strong> 48 ~ 52Hz or 57 ~ 63Hz<br /><strong>Frequency Range (Batt. Mode):</strong> 50Hz &plusmn; 0.25Hz or 60Hz &plusmn; 0.3Hz<br /><strong>Current Crest Ratio:</strong> 3:1<br /><strong>Harmonic Distortion: </strong>4 % THD (Linear Load) &amp; 7 % THD (Non-linear Load)</p>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p><strong>Transfer Time (AC Mode to Batt. Mode):</strong> Zero<br /><strong>Inverter to Bypass:</strong> 4 ms<br /><strong>Phase:</strong> Single phase with ground<br /><strong>Power Factor:</strong> 0.98</p>
<h3>Output</h3>
<p><strong>AC Voltage Regulation (Batt. Mode): </strong>&plusmn; 3%<br /><strong>Capacity: </strong>3000VA / 2400W<br /><strong>Waveform (Batt. Mode):</strong> Pure Sinewave<br /><strong>Efficiency: </strong>AC Mode: 88%, Battery Mode: 83%<br /><strong>Battery Type:</strong> 12 V / 9 AH<br /><strong>Numbers:</strong> 6<br /><strong>Typical Recharge Time:</strong> 4 hours recover to 90% capacity<br /><strong>Charging Current (max.):</strong> 1.0 A<br /><strong>Charging Voltage:</strong> 82.1 VDC &plusmn; 1%</p>