	<item>
		<title>HV Diagnostics TD30 Tan Delta Set</title>
		<link>http://www.precisefacilities.com.au/product/hv-diagnostics-td30-tan-delta-set/</link>
		<comments>http://www.precisefacilities.com.au/product/hv-diagnostics-td30-tan-delta-set/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 07:33:48 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=78</guid>
		<description><![CDATA[<p>The HV Diagnostics TD30 is a versatile tan delta measuring system that is directly connected to the HVA30 series of VLF test systems. The tan delta of the test object can now be quickly measured and the results stored thus providing a signature of the device being tested. The TD30 is suitable for testing cables: XLPE, PE, EPR,PILC etc, capacitors, switchgear, transformers, rotating machines, insulators and bushings.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-diagnostics-td30-tan-delta-set/">HV Diagnostics TD30 Tan Delta Set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<div>
<p>The HV Diagnostics TD30 is a battery powered system that is directly connected to the HVA30 series of VLF test systems. The standard C size alkaline battery cells last for up to 10 hours providing the capacity for many tests to be performed. The TD30 is supplied with 10 metres of output cable which is already terminated to suit the HVA30 test system. Companion operating software gives a complete picture of the tan delta measurement together with a real time display of the output voltage and current. The data transmission is via Bluetooth eliminating the need for a direct connection between the TD30 and the data collection device.<b></b></p>
<h3>Brief Specs:</h3>
</div>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4><span style="line-height: 1.5em;">Supply Voltage:</span></h4>
<ul>
<li> 2 type “C” alkaline cells (typically 10 hours measurement)</li>
</ul>
<h4>Operating/Measured Voltage</h4>
<ul>
<li>Sinusoidal: 1– 23 kV RMS</li>
<li>Frequency: 0.1Hz</li>
</ul>
<h4>Voltage Measurement</h4>
<ul>
<li>Resolution: 0.1 kV RMS</li>
<li>Accuracy: 1% of reading</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Current Measurement</h4>
<ul>
<li>Resolution: 1 uA RMS</li>
<li>Accuracy: 1% of reading</li>
</ul>
<h4>Tan Delta Measurement</h4>
<ul>
<li>Resolution: 1 x 10-5</li>
<li>Accuracy:
<ul>
<li>± 1 x 10-4 (load &gt; 15nF)</li>
<li>± 3 x 10-4 (load &lt; 15nF)</li>
</ul>
</li>
</ul>
<h4>Load range</h4>
<ul>
<li>Standard: 15nF to 5μF</li>
<li>Lower Accuracy: 1nF to 15nF</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-diagnostics-td30-tan-delta-set/">HV Diagnostics TD30 Tan Delta Set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/hv-diagnostics-td30-tan-delta-set/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>HV Diagnostics TD60 Tan Delta Set</title>
		<link>http://www.precisefacilities.com.au/product/hv-diagnostics-td60-tan-delta-set/</link>
		<comments>http://www.precisefacilities.com.au/product/hv-diagnostics-td60-tan-delta-set/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 07:34:51 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=79</guid>
		<description><![CDATA[<p>The TD60 provides the testing and commissioning engineer with a high voltage tan delta measuring system suitable for testing cables: XLPE, PE, EPR, PILC and other electrical equipment: capacitors, switchgear, transformers and rotating machines. The TD60 is a versatile tan delta measuring system that is directly connected to the HVA60 series of VLF Test Systems. The tan delta of the test object can be measured quickly and the results stored providing a signature of the cable being tested.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-diagnostics-td60-tan-delta-set/">HV Diagnostics TD60 Tan Delta Set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The TD60 provides the testing and commissioning engineer with a high voltage tan delta measuring system suitable for testing cables: XLPE, PE, EPR, PILC and other electrical equipment: capacitors, switchgear, transformers and rotating machines. The TD60 is a versatile tan delta measuring system that is directly connected to the HVA60 series of VLF Test Systems. The tan delta of the test object can be measured quickly and the results stored providing a signature of the cable being tested.<b></b></p>
<h3>Brief Specs:</h3>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Input Voltage</h4>
<ul>
<li>2 type “C” alkaline cells</li>
</ul>
<h4>Operating Conditions</h4>
<ul>
<li>Voltage: 0 &#8211; 44 kV RMS</li>
<li>Current: 0.001mA – 36mA RMS</li>
<li>Frequency: 0.1 Hz</li>
</ul>
<h4>Voltage Measurement</h4>
<ul>
<li>Resolution: 0.1kV RMS</li>
<li>Accuracy: 0.5% of reading</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Current Measurement</h4>
<ul>
<li>Resolution: 1 µA RMS</li>
<li>Accuracy: 1% of reading</li>
</ul>
<h4>Tan Delta Measurement</h4>
<ul>
<li>Resolution: 0.1 x 10-3</li>
<li>Accuracy: ± 0.3 x 10<sup>-3</sup> (load &gt; 15nF and &lt; 500nF)</li>
<li>± 0.5 x 10<sup>-3</sup> (load &lt; 15nF and &gt; 500nF)</li>
<li>Minimum Load: 5nF</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-diagnostics-td60-tan-delta-set/">HV Diagnostics TD60 Tan Delta Set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/hv-diagnostics-td60-tan-delta-set/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Omicron CP TD1 Tan Delta / PF Test Set</title>
		<link>http://www.precisefacilities.com.au/product/omicron-cp-td1-tan-delta-pf-test-set/</link>
		<comments>http://www.precisefacilities.com.au/product/omicron-cp-td1-tan-delta-pf-test-set/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 08:14:32 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=107</guid>
		<description><![CDATA[<p>The condition of the insulation is an essential aspect for the operational reliability of electrical power transformers, generators, and other high voltage equipment. The use of a CPC 100 with a CP TD1 provides laboratory precision for capacitance and dissipation / power factor measurements in the field. Quantities measured include, capacitance Cp, dissipation factor tanδ(tangent delta), power factor cos ϕ, power (active, reactive, apparent) and impedance (absolute value, phase, inductivity, resistance, Q).</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/omicron-cp-td1-tan-delta-pf-test-set/">Omicron CP TD1 Tan Delta / PF Test Set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>Combined with the CPC 100, the CP TD1 measures the capacitance and dissipation factor (power factor) with laboratory precision. This allows the insulation condition of transformers, generators and other parts of high-voltage systems to be tested according to IEEE 62 (C57.152), IEC 60076-1 and -3, as well as the CIGRE &#8220;Guide for Transformer Maintenance&#8221;. As recommended in the CIGRE Guide, testing is performed at variable frequencies to better diagnose signs of ageing in insulation. The portable test system can also generate output voltages of up to 12 kV.</p>
<h3>Brief Specs:</h3>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>High Voltage Output</h4>
<ul>
<li>V: 0&#8230;12 kV AC</li>
<li>I, t<sub>max</sub>: 300mA &gt;2 min, 100mA &gt;60 min</li>
<li>F (Hz): 15…400</li>
</ul>
<h4>Internal measurement of voltage output/current inputs</h4>
<ul>
<li>Range: 12000 V AC, Resolution: 1 V, Accuracy: error &lt;0.3% reading + 1V</li>
<li>Range: 5 A AC, Resolution: 5 digits, Accuracy: error &lt; 0.5% reading</li>
<li>Range: 8 mA AC, Resolution: 5 digits, Accuracy: error &lt; 0.3% + 100nA</li>
</ul>
<h4>Capacitance Cp (equivalent parallel circuit)</h4>
<ul>
<li>Range: 1 pF…3 µF, Resolution: 6 digits, Accuracy: error &lt; 0.05% reading + 0.1 pF, Conditions: &lt; 8 mA</li>
<li>Range: 1 pF…3 µF, Resolution: 6 digits, Accuracy: error &lt; 0.2% reading + 0.1 pF, Conditions: &gt; 8 mA</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Dissipation factor DF (tan δ)</h4>
<ul>
<li>Range: 0&#8230;10% (capacitive), Resolution: 5 digits,</li>
<li>Accuracy: error &lt; 0.1% reading + 0.005%, Conditions: 15&#8230;70 Hz, &lt; 8 mA</li>
<li>Range: 0…100 (0…10000%), Resolution: 5 digits, Accuracy: error &lt; 0.5% reading + 0.02%</li>
</ul>
<h4>Power factor cos ϕ</h4>
<ul>
<li>Range: 0…10% (capacitive), Resolution: 5 digits,</li>
<li>Accuracy: error &lt; 0.1% reading + 0.005%, Conditions: 15…70 Hz, &lt; 8mA</li>
<li>Range: 0…100%, Resolution: 5 digits, Accuracy: error &lt; 0.5% reading + 0.02%</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/omicron-cp-td1-tan-delta-pf-test-set/">Omicron CP TD1 Tan Delta / PF Test Set</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/omicron-cp-td1-tan-delta-pf-test-set/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>