<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title> &#187; Products</title>
	<atom:link href="http://www.precisefacilities.com.au/products/feed/?product_cat=line-impedance" rel="self" type="application/rss+xml" />
	<link>http://www.precisefacilities.com.au</link>
	<description></description>
	<lastBuildDate>Mon, 01 Jul 2019 02:24:32 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	
	<item>
		<title>Omicron CU1 with GB1 Line Impedance Tester</title>
		<link>http://www.precisefacilities.com.au/product/omicron-cu1-with-gb1-line-impedance-tester/</link>
		<comments>http://www.precisefacilities.com.au/product/omicron-cu1-with-gb1-line-impedance-tester/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 08:22:09 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=111</guid>
		<description><![CDATA[<p>The Omicron CP CU1 used in combination with the Omicron CPC 100 measures line impedances and k-factors on overhead lines and power cables. Ground impedances can also be determined on large systems with the CP CU1, as well as touch and step voltages. Mains frequency malfunctions do not influence the measurements, as the CPC 100 and CP CU1 use variable output frequencies for measurements. This enables extremely precise and producible measurement results. To increase safety for the test engineer, the CP GB1 grounding unit is supplied with the CP CU1. This can divert currents of up to 30 kA if its voltage limit value is exceeded.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/omicron-cu1-with-gb1-line-impedance-tester/">Omicron CU1 with GB1 Line Impedance Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>By generating signals and using selective measurements different from the power system frequency, the combination of an Omicron CPC 100 and an Omicron CP CU1 is able to obtain very accurate results. The CP CU1 coupling unit is used to safely connect the inputs and outputs of the CPC 100 to a transmission line. The grounding box CP GB1 is used to make the connection between the CP CU1 and the overhead line and can be located at a safe distance from the operator.</p>
<p>To measure line impedance and k-Factor or the mutual coupling factor, the CPC 100 and CP CU1 operate at a nonsystem frequency allowing the user to measure all fault loop configurations (phase to ground, phase to phase and three phase to ground). This provides accurate measurement of impedance magnitude and phase angle for lines with lengths of up to 300 km.</p>
<p>Conventional ground impedance test methods using power system frequencies need enormous power and complicated methods to overcome the problems of interference. By varying the frequency and using narrowband digital filtering with the CPC 100 and CP CU1 reduces the required power to a minimum. The inductive coupling impedance between a power system and adjacent cables can also be measured using the CPC 100 and CP CU1 test system.</p>
<h3>Brief Specs:</h3>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			<hr class="vcex-spacing " style="height: 20px" />
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p><strong>CP CU1<br />
Current Output Ranges</strong></p>

		</div> 
	</div> <div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>Current range<br />
0 &#8230; 10 A rms<br />
0 &#8230; 20 A rms<br />
0 &#8230; 50 A rms<br />
0 &#8230; 100 A rms</p>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>Compliance voltage<br />
500 V rms<br />
250 V rms<br />
100 V rms<br />
50 V rms</p>

		</div> 
	</div> </div>
	</div> 
</div></div><hr class="vcex-spacing " style="height: 20px" />
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p><strong>Measuring Transformers</strong><br />
VT    600 V : 30 V class 0.1<br />
CT    100 A : 2.5 A class 0.1</p>

		</div> 
	</div> <hr class="vcex-spacing " style="height: 20px" />
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p><strong>CP GB1<br />
Electrical Data</strong><br />
Nominal ac spark-over voltage <1000 V rms
Short circuit proof up to 30 kA for 100 ms&#091;/vc_column_text&#093;&#091;/vc_column&#093;&#091;vc_column width="1/2"&#093;&#091;vcex_spacing size="20px"&#093;&#091;vc_column_text&#093;<strong>Overall System<br />
Output Power</strong><br />
5000 VA, cos j < 1.0 for 8 s @ 230 V ac mains voltage
5000 VA, cos j < 0.4 for 8 s @ 115 V ac mains voltage&#091;/vc_column_text&#093;&#091;vcex_spacing size="20px"&#093;&#091;vc_column_text&#093;<strong>Accuracy</strong></p>

		</div> 
	</div> <div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span4 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>Measured value<br />
0.05 &#8211; 0.2 &Omega;<br />
0.2 &#8211; 2 &Omega;<br />
2 &#8211; 5 &Omega;<br />
5 &#8211; 25 &Omega;<br />
25 &#8211; 300 &Omega;</p>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span4 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>Typical accuracy<br />1.0 &#8211; 0.5 %<br />0.5 &#8211; 0.3 %<br />0.3 %<br />0.3 %<br />0.3 % &#8211; 1.0 %</p>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span4 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>Current<br />range<br />100 A<br />100 A<br />50 A<br />20 A<br />10 A</p>

		</div> 
	</div> </div>
	</div> 
</div></div></div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/omicron-cu1-with-gb1-line-impedance-tester/">Omicron CU1 with GB1 Line Impedance Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/omicron-cu1-with-gb1-line-impedance-tester/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>