<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title> &#187; Products</title>
	<atom:link href="http://www.precisefacilities.com.au/products/feed/?product_cat=hi-potential-testers" rel="self" type="application/rss+xml" />
	<link>http://www.precisefacilities.com.au</link>
	<description></description>
	<lastBuildDate>Mon, 01 Jul 2019 02:24:32 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	
	<item>
		<title>Hipotronics 815PL-B 15KV DC Hipot Tester</title>
		<link>http://www.precisefacilities.com.au/product/hipotronics-815pl-b-15kv-dc-hipot-tester/</link>
		<comments>http://www.precisefacilities.com.au/product/hipotronics-815pl-b-15kv-dc-hipot-tester/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 07:28:34 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=72</guid>
		<description><![CDATA[<p>A compact, lightweight and rugged instrument suitable for field oriented applications, the 815PL DC Hipot can be used for the testing of numerous electrical system components. The minimal setup time, easy to use control panel and guard circuit to prevent any leakage currents enables for accurate and efficient testing. The feature of grounding the power supply and test object whenever the high voltage is switched off maintains a high level of operator safety.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hipotronics-815pl-b-15kv-dc-hipot-tester/">Hipotronics 815PL-B 15KV DC Hipot Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The Hipotronics 815PL-B 15KV DC Hipot tester features accurate kV meter readings regardless of load current. Accurate voltage and current measurements are assured via voltage readings that are taken directly at the output of the high voltage transformer and current measurements are taken in the return leg. Safe discharging of both the test object and the high voltage transformer occur whenever the high voltage is turned off. Output power is provided by means of a full-wave voltage doubling rectifier circuit with silicon rectifiers. The set is self-contained in a single, rugged and durable enclosure which is complete from input line cord to high voltage output cable with cable storage space conveniently located inside. The Hipotronics 815PL-B can be used for the DC Hipot testing of cables, transformers, electrical switchgear, motors, generators and various other electrical apparatus.</p>
<h3>Brief Specs:</h3>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Input Voltage</h4>
<ul>
<li>230 V, 50/60 Hz</li>
</ul>
<h4>Output Voltage</h4>
<ul>
<li>0 &#8211; 80 kV</li>
</ul>
<h4>Output Current</h4>
<ul>
<li>10 mA</li>
</ul>
<h4>Polarity</h4>
<ul>
<li>Negative output, positive ground</li>
</ul>
<h4>Metering</h4>
<ul>
<li>± 2% full scale accuracy</li>
</ul>
<h4>Ripple</h4>
<ul>
<li>0.5% per mA with rated resistance</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Features<b><br />
</b></h4>
<ul>
<li>Rugged, portable single-piece construction</li>
<li>Shielded output cable</li>
<li>Full-wave voltage doubling rectifier circuit</li>
<li>Zero start interlock and guard circuit</li>
<li>Internal discharge solenoid</li>
<li>Meter accuracy ± 2% full scale</li>
<li>10 mA current rating for cable charging</li>
<li>External interlock provisions</li>
<li>Three range voltmeter</li>
<li>Four range current meter</li>
<li>No internal leakage at full load</li>
<li>Instantaneous overload relay</li>
<li>Surge-limiting resistors in HV output</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hipotronics-815pl-b-15kv-dc-hipot-tester/">Hipotronics 815PL-B 15KV DC Hipot Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/hipotronics-815pl-b-15kv-dc-hipot-tester/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Hipotronics 860PL-B 60kV DC Hipot Tester</title>
		<link>http://www.precisefacilities.com.au/product/hipotronics-860pl-b-60kv-dc-hipot-tester/</link>
		<comments>http://www.precisefacilities.com.au/product/hipotronics-860pl-b-60kv-dc-hipot-tester/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 07:29:03 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=73</guid>
		<description><![CDATA[<p>The Hipotronics 860PL DC insulation tester is designed to be a fully instrumented, easy to use, high voltage proof tester. The unit features rugged construction, conservatively rated components and built in surge devices to help protect against damage from repeated short circuits at full output. The 860PL operates from an input of 120 volts ac, 50/60 Hz, 5 amps. Rated output current is 5 mA for 15 minutes. (Capacitor Charging Duty)</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hipotronics-860pl-b-60kv-dc-hipot-tester/">Hipotronics 860PL-B 60kV DC Hipot Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The Hipotronics 860PL-B DC hipot tester provides a solution to the DC field testing of cables, terminations, motors, generators and other electrical apparatus. The model is self contained in a single rugged and durable enclosure with cables conveniently stored inside the case. The Hipotronics 860PL-B tester produces accurate kV meter readings regardless of load current. Accurate voltage and current measurements are assured since voltage readings are taken directly at the output of the high voltage transformer and current measurements are taken in the return leg. The safe discharging of both the test object and the high voltage transformer occurs whenever the high voltage is turned off and output power is provided by means of a full-wave voltage doubling rectifier circuit with silicon rectifiers.<b></b></p>
<h3>Brief Specs:</h3>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Input Voltage</h4>
<ul>
<li>220 volt 50Hz</li>
</ul>
<h4>Output Voltage</h4>
<ul>
<li>0 to 60kV</li>
</ul>
<h4>Output Current</h4>
<ul>
<li>5mA</li>
</ul>
<h4>Polarity</h4>
<ul>
<li>Negative output, positive ground</li>
</ul>
<h4>Metering</h4>
<ul>
<li>±2% full scale accuracy</li>
</ul>
<h4>Ripple</h4>
<ul>
<li>Less than 2.5%</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Features</h4>
<ul>
<li>Shielded output cable.</li>
<li>Guard circuit.</li>
<li>Full-wave voltage doubling rectifier circuit.</li>
<li>Zero start interlock.</li>
<li>Internal discharge on HV OFF.</li>
<li>Meter accuracy ±2% of full scale.</li>
<li>5mA current rating for cable charging.</li>
<li>External interlock provisions.</li>
<li>Three range voltmeter.</li>
<li>Four range current meter.</li>
<li>No internal leakage at full load.</li>
<li>Instantaneous overload relay.</li>
<li>Surge-limiting resistors in HV output.</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hipotronics-860pl-b-60kv-dc-hipot-tester/">Hipotronics 860PL-B 60kV DC Hipot Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/hipotronics-860pl-b-60kv-dc-hipot-tester/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>HV Inc ALT-120/60 120kV AC Hipot Tester</title>
		<link>http://www.precisefacilities.com.au/product/hv-inc-alt-12060-120kv-ac-hipot-tester/</link>
		<comments>http://www.precisefacilities.com.au/product/hv-inc-alt-12060-120kv-ac-hipot-tester/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 07:36:39 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=81</guid>
		<description><![CDATA[<p>Designed to meet ANSI A92.2 testing, the ALT-120/60 delivers up to 120 kV for boom testing and up to 7 kVA of power for testing nearly all liners and other high capacitance loads requiring an AC withstand test. The 0–60 kVac/0–120 kVac model ALT-120/60 provides a power rating of 7 kVA capacitive for one hour – 4 kVA resistive continuous duty. It offers a 250 uA current meter range, rugged, transit protected, anti-static glass front meters, a guard/ground circuit, test timer, and an internal voltmeter divider.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-inc-alt-12060-120kv-ac-hipot-tester/">HV Inc ALT-120/60 120kV AC Hipot Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The HV Inc ALT-120/60 AC hipot tester&nbsp;is a portable high voltage AC test set that is rugged, reliable, economical, contains advanced features and provides long term duty ratings. The ALT-120 is designed to provide continuously adjustable AC output up to 120 kV with a full kVA tap at 60 kV and is rated for 7 kVA of power, enabling it to meet all testing requirements. The generous duty rating allows many tests to be performed&nbsp;sequentially or use the unit for other extended time testing applications.</p>
<p>The HV Inc ALT-120/60 AC hipot tester also incorporates transit protection meter circuits, an optional capacitive load current cancellation circuit which allows the user to read resistive currents, guard/ground return for isolating ground currents to measure leakage current or total current, zero start high voltage and external safety interlock provision, a cable storage area,&nbsp;internal kilovolt meter divider resistors (no external voltmeter divider), test timer circuit and ruggedized meters with glass windows that eliminate static build up.</p>
<h4>Brief Specs:</h4>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Input</h4>
<ul>
<li>230 V, 5 0/60 H z, 15 A</li>
</ul>
<h4>Output</h4>
<ul>
<li>0-120 k Vac / 0-60 kVac</li>
</ul>
<h4>Load Rating</h4>
<ul>
<li>7 kVA Capacitive (1.3 nF @ 120 kV, 5.3 n F @ 60 kV )</li>
</ul>
<h4>Duty Cycle</h4>
<ul>
<li>7 kVA for 1 hour on / 2 h ours off, 4 kVA continuous</li>
</ul>
<h4>Output Termination</h4>
<ul>
<li>Top toroid for 120 kV, side tap for 60 kV</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Distortion</h4>
<ul>
<li>&lt;5%</li>
</ul>
<h4>Meter Accuracy</h4>
<ul>
<li>2% of full scale, analog</li>
</ul>
<h4>Voltmeter</h4>
<ul>
<li>3.5&#8243; scaled 0-30/60kV and 0-60/120kV AC RMS</li>
</ul>
<h4>Currentmeter</h4>
<ul>
<li>3.5&#8243; 0-250 µa and 0-1.0 mA with multipliers:
<ul>
<li>x1, x10, x100 up to 100 mA</li>
</ul>
</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-inc-alt-12060-120kv-ac-hipot-tester/">HV Inc ALT-120/60 120kV AC Hipot Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/hv-inc-alt-12060-120kv-ac-hipot-tester/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>HV Inc PFT-5030 50kV AC Hipot Tester</title>
		<link>http://www.precisefacilities.com.au/product/hv-inc-pft-5030-50kv-ac-hipot-tester/</link>
		<comments>http://www.precisefacilities.com.au/product/hv-inc-pft-5030-50kv-ac-hipot-tester/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 07:38:22 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=82</guid>
		<description><![CDATA[<p>The PFT-5030 is a single piece, 50 kVac @ 3 kVA, shielded cable output Hipot tester. Output voltage is continuously adjustable and the tester utilizes a dual range kilovoltmeter and triple range output current meter. Also featuring external and zero start safety interlocks, the PFT-5030 is a versatile tool when undertaking AC testing.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-inc-pft-5030-50kv-ac-hipot-tester/">HV Inc PFT-5030 50kV AC Hipot Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The HV Inc PFT-5030 50kV AC Hipot Tester is ideal for a variety of field and repair shop testing applications. The compact and light weight tester is rugged and reliable. Capacitive load compensation enables full load testing with a power draw of 1.5 kVA while operating from a conventional line input. The HV Inc PFT-5030 50kV AC Hipot Tester is well suited for testing overhead apparatus, vacuum bottles and interrupters, switch gear, bus duct, motorized vacuum switches, reclosers, bushings, fuses and arrestors, linemans safety products, small transformers, electrical components and motors.  Control features include a dual range kilovoltmeter and triple range output current meter. Additionally the tester has a continuously adjustable output voltage control, external safety interlock, zero start safety interlock, self-resetting over current protection, guard/ground return mode, HV on/off and main power pushbuttons and ruggedized meters with glass windows that eliminate static build up.<b></b></p>
<h3>Brief Specs:</h3>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Input</h4>
<ul>
<li>230 V, 50/60 Hz, 8A</li>
</ul>
<h4>HV Output</h4>
<ul>
<li>0-50 kVac, 1kVA resistive load</li>
<li>3 kVA capacitive load</li>
<li>Up to 60 mA current</li>
</ul>
<h4>No Load Current</h4>
<ul>
<li>20 mA (at full output voltage in ground mode but not guard mode)</li>
</ul>
<h4>Duty</h4>
<ul>
<li>3kVA: 1 hour ON, 1 hour OFF</li>
<li>1kVA: continuous</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Distortion</h4>
<ul>
<li>&lt;5%</li>
</ul>
<h4>Meter Accuracy</h4>
<ul>
<li>2% F.S.</li>
</ul>
<h4>Kilovolt Meter</h4>
<ul>
<li>3.5 inch scaled 0-25/50 kVac</li>
</ul>
<h4>Current Meter</h4>
<ul>
<li>3.5 inch, Scaled 0-1.0 mAac with x1, x10, x100 Range Multiplier</li>
</ul>
<h4>Output Termination</h4>
<ul>
<li>6m long shielded output cable with alligator clamp and hook</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/hv-inc-pft-5030-50kv-ac-hipot-tester/">HV Inc PFT-5030 50kV AC Hipot Tester</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/hv-inc-pft-5030-50kv-ac-hipot-tester/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>