		<title>Omicron CT Analyser</title>
		<link>http://www.precisefacilities.com.au/product/omicron-ct-analyser/</link>
		<comments>http://www.precisefacilities.com.au/product/omicron-ct-analyser/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 08:20:19 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=110</guid>
		<description><![CDATA[<p>The Omicron CT Analyzer is a complete testing system for protection and metering CTs according to IEEE and IEC standards. It allows all types of single and multi-ratio current transformers to be tested on-site in power system grids.  It can also be used to calibrate instrument transformers due to its high level of accuracy.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/omicron-ct-analyser/">Omicron CT Analyser</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The Omicron CT Analyser is the optimal device for testing instrument transformers for billing purposes, as well as for testing protection transformers, including those with transient behavior. It is ideal for usage in the field due to its light weight of just 8 kg, high noise immunity and Automatic assessment according to IEEE and IEC standards. The CT Analyzer offers a wide range of measurements, such as CT-ratio and phase-angle accuracy with consideration of nominal and operational burden for various currents, CT winding resistance, CT excitation / saturation (unsaturated and saturated), ALF and FS (direct and indirect), burden impedance and CT residual magnetism within minutes with just one test cycle.</p>
<h3> Brief Specs:</h3>
<ul>
<li>Automatic assessment according to IEC 60044-6, or IEEE C57.13 up to accuracy class ≥ 0.3</li>
<li>Determination of ALF/ALFi and FS/FSi, Ts, and composite error for nominal and connected burden</li>
<li>CT ratio and phase measurement with consideration of nominal and connected secondary burden
<ul></li>
<li>Currents from 1% up to 400 % of the rated value</li>
<li>Different burdens (full, ½, ¼, ⅛ burden)</li>
</ul>
</li>
<li><span style="line-height: 1.5em;">CT winding resistance measurement (primary and secondary)</span></li>
<li><span style="line-height: 1.5em;">CT excitation curve (unsaturated and saturated)</span>
<ul style="line-height: 1.5em;">
<li>Saturation characteristic recording</li>
<li>Direct comparison of excitation curve to a reference curve</li>
</ul>
</li>
<li><span style="line-height: 1.5em;">CT phase and polarity check</span></li>
<li><span style="line-height: 1.5em;">Secondary burden measurement</span></li>
<li><span style="line-height: 1.5em;">Automatic demagnetization of the CT after the test</span></li>
<li><span style="line-height: 1.5em;">High level of safety using patented variable frequency method (max. 120 V)</span></li>
<li><span style="line-height: 1.5em;">&#8220;Nameplate guesser&#8221; function for CTs with unknown data</span></li>
<li><span style="line-height: 1.5em;">Remote control interface</span></li>
<li><span style="line-height: 1.5em;">Simulation of measured data with different burdens and currents</span></li>
<li><span style="line-height: 1.5em;">Knee-point voltage from 1 V up to 30 kV can be measured</span></li>
<li><span style="line-height: 1.5em;">Automatic assessment for accuracy class &gt; 0.1 (inclusive classes defined in the IEEE C57.13.6 standard)</span></li>
<li><span style="line-height: 1.5em;">Measurement of transient behavior of TPS, TPX, TPY and TPZ type CTs</span></li>
<li><span style="line-height: 1.5em;">Determination of the transient dimensioning factor (Ktd) </span>Considering Duty (C-O / C-O-C-O) e.g. auto-reclosure system</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/omicron-ct-analyser/">Omicron CT Analyser</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.precisefacilities.com.au/product/omicron-ct-analyser/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Vanguard EZCT10 CT Analyser</title>
		<link>http://www.precisefacilities.com.au/product/vanguard-ezct10-ct-analyser/</link>
		<comments>http://www.precisefacilities.com.au/product/vanguard-ezct10-ct-analyser/#comments</comments>
		<pubDate>Mon, 24 Feb 2014 08:43:37 +0000</pubDate>
		<dc:creator><![CDATA[IT Support]]></dc:creator>
		
		<guid isPermaLink="false">http://www.precisefacilities.com.au/?post_type=product&#038;p=127</guid>
		<description><![CDATA[<p>The Vanguard EZCT10 current transformer analyser performs excitation tests as specified by the ANSI/IEEE C57.13.1, IEC 60044-1 methodology. It also has a built-in thermal printer that can plot up to 10 knee-point voltages and excitation curves. The EZCT10 can also determine the current-ratio of current transformers using the ANSI/IEEE C57.12.90 measurement technique. Winding polarity is displayed as in-phase (+) or out-of-phase (-) sign and annotated with the phase angle.</p>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/vanguard-ezct10-ct-analyser/">Vanguard EZCT10 CT Analyser</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>
]]></description>
				<content:encoded><![CDATA[<div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span12 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p>The Vanguard EZCT10 is a microprocessor-based, current-transformer test set that measures excitation current, turns ratio and winding polarity on single and multi-ratio current transformers. Current transformers can be tested in their field-mounted configuration, eliminating the need to remove bushings or current transformers from the host equipment. The test set determines the current-transformer turns ratio by accurately measuring the voltages across the primary and secondary windings (a direct proportion) and then displaying the voltage ratio. Turns ratio is measured from 0.8 through 5,000 to 1.0 with an accuracy of 0.5% or better. Winding polarity displays as a + or &#8211; sign and is also annotated with the phase in degrees.<b></b></p>
<h3>Brief Specs:</h3>

		</div> 
	</div> </div>
	</div> 
</div></div><div  class="wpb_row clr vc_row-fluid " ><div class="clr  " >
	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Output Test Voltage</h4>
<ul>
<li>0 to 50V ac @ 10A max.</li>
<li>0 to 250C ac @ 10A max.</li>
<li>0 to 1,200V ac @ 1.5A max. (5 min ON, 10 min OFF)</li>
</ul>
<h4>Voltage Reading Range</h4>
<ul>
<li>0 to 1250V, Accuracy: ± 1.0% of reading, ± 0.5V</li>
</ul>
<h4>Current Reading Range</h4>
<ul>
<li>0 to 10A, Accuracy: ± 1.0% of reading, ± 0.02A</li>
</ul>
<h4>Turns-Ratio Range</h4>
<ul>
<li>0.8 to 99, Accuracy: ± 1.0%</li>
<li>100 to 999, Accuracy: ± 2.0%</li>
<li>1000 to 5000, Accuracy: ± 3.0%</li>
</ul>

		</div> 
	</div> </div>
	</div> 

	<div class="vc_span6 wpb_column column_container  "><div class="clr vcex-skin-default " >
			
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<h4>Phase Angle Measurement</h4>
<ul>
<li>0 to 360 Degrees, Accuracy: ± 1.0 degree</li>
</ul>
<h4>Display</h4>
<ul>
<li>Backlit, 4 lines by 20 characters</li>
</ul>
<h4>Test Storage</h4>
<ul>
<li>128 Test records (of 10 curves)</li>
</ul>
<h4>Computer Interface</h4>
<ul>
<li>RS-232, 19,200 Baud</li>
</ul>
<h4>Operating Temperature</h4>
<ul>
<li>-10°C to 50°C</li>
</ul>
<h4>Storage Temperature</h4>
<ul>
<li>-30°C to 70°C</li>
</ul>

		</div> 
	</div> </div>
	</div> 
</div></div>
<p>The post <a rel="nofollow" href="http://www.precisefacilities.com.au/product/vanguard-ezct10-ct-analyser/">Vanguard EZCT10 CT Analyser</a> appeared first on <a rel="nofollow" href="http://www.precisefacilities.com.au"></a>.</p>